Windpumps
A windpump uses energy from the wind to lift or move water. A mechanical windpump drives a pump through a physical linkage. A wind-electric system uses a turbine to generate electricity for a motor-driven pump. Both can fill a tank when the wind is favourable, allowing water to be used at other times. This article follows the Food and Agriculture Organization's Water Lifting Devices for pump performance and the U.S. Centers for Disease Control and Prevention (CDC) for drinking-water guidance.[1][2][3]

How the systems work
| System | Path from wind to water | Design implications |
|---|---|---|
| Direct mechanical | A rotor turns a crank, often through reduction gearing. A pump rod moves up and down to drive a piston in the well. Valves in the pump convert the alternating stroke into flow in one direction. | The classic multibladed farm rotor has high starting torque and runs at low speed, which suits a piston pump. The tower ordinarily stands over the well or borehole because the pump rods run directly down to the pump. Pump load affects the wind speed needed to start.[1][4] |
| Wind-electric | A turbine drives a generator. Electrical controls match the supply to a motor-pump, which can be submerged in a borehole. | Cable allows the turbine to stand at a better wind site away from the well. It tends to cost more, but the electricity can serve other uses when not pumping and can be stored in batteries for low-wind periods. The control system must suit the generator and motor. The U.S. Department of Energy notes that a mechanical windmill can be more efficient in low-wind areas.[4][5] |
A larger piston or a longer stroke can move more water per stroke, but the increased load can keep a mechanical pump stopped in light winds. A tail vane keeps the rotor facing the wind. On many farm windpumps the tail vane is also designed to turn the rotor out of the wind in strong winds, a process called furling, to prevent damage. The limits and shutdown method depend on the machine.[1][4]
Wind resource and expected delivery
The power available in moving air scales with the cube of wind speed for a given rotor area and air density. Water delivery does not follow that relationship across the whole wind range. The pump must start, its efficiency changes, and the machine may limit output or stop in stronger winds. Buildings, trees and terrain affect both speed and turbulence, and wind speed generally increases with height, so a regional map or airport record is only a screening tool. Compare conditions at the intended rotor height, including seasonal winds and calm spells, and obtain performance data for the rotor, pump and head as a combination.[1][5]
Estimate delivery over the months when water is needed. Group the observed wind hours by speed, multiply each group's hours by the corresponding pump flow, and add the resulting volumes. In one FAO example, a speed group representing 400 hours at 4.5 metres per second has an output of 3 cubic metres per hour, contributing 1,200 cubic metres to that example's annual total. The values describe one example, not a rating for other pumps. A monthly sum estimates yield, while the sequence of calm days determines how long storage must cover a shortfall.[1]
Lift, demand and storage
For a well, start with the water level while pumping. The lowering of the water level as water is extracted is called drawdown, and it generally increases with the extraction rate. The static head is the vertical distance the water is actually raised, from the pumping water level to the delivery point. Friction in the pipe, and the extra turbulence at bends, valves and junctions, adds friction head at the expected flow. Together with a small velocity head, these make up the total head the pump must work against. Raising a tank can improve gravity delivery but also increases the pumping lift. Do not pump the source faster than it can supply.[6][1]
Estimate daily demand separately for each use and for the season when it is highest. For water at sea level, Practical Action gives the approximate energy required as E = 0.002725 x volume x head, in kilowatt-hours, with the volume in cubic metres and the head in metres. That is the energy delivered to the water. The wind-driven shaft or the electrical supply must furnish more energy because of conversion losses, so this estimate alone cannot select a rotor or motor-pump.[4][6]
Storage lets water use continue while the pump is stopped. FAO notes that wind only works under certain weather conditions, and that a storage tank is generally the most cost-effective way to store the output, since batteries become expensive as their capacity grows. Check how often the tank would refill, how much capacity is below its outlet, and what happens during a longer calm or equipment outage. A larger tank cannot compensate for a sustained shortfall in supply.[2][1]
Installation and water quality
Have the tower, foundation, storm protection and any elevated tank support reviewed for the site. Check local zoning and permit requirements, which may limit tower height, and electrical requirements. If you cannot pour a proper foundation, erect the tower safely or wire the system, hire an installer. Arrange safe access for maintenance and follow the manufacturer's operation and maintenance plan, including its shutdown procedure, before servicing moving machinery. Keep records of tank levels, flow and maintenance to distinguish a wind shortfall from declining well yield or pump performance.[5][1]
Pumping does not make source water safe to drink. For a private well used for drinking, CDC advises testing the water at least once each year for total coliform bacteria, nitrates, total dissolved solids and pH. Ask the local health department which other germs or chemicals to test for. Test again if there are reported problems in the area, after flooding or land disturbance near the well, after repairing or replacing part of the well system, or if the water's taste, colour or smell changes. Keep stored drinking water covered and protected from contamination; for household containers CDC advises food-grade containers with tight lids, kept away from sunlight and toxic substances.[3][7]
See also
References
- ↑ 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 Water Lifting Devices, section 4.7: Wind Power. FAO. Retrieved 21 November 2026.
- ↑ 2.0 2.1 Water Lifting Devices, section 4.1: Prime movers as part of a pumping system. FAO. Retrieved 21 November 2026.
- ↑ 3.0 3.1 Guidelines for Testing Well Water. CDC. Retrieved 21 November 2026.
- ↑ 4.0 4.1 4.2 4.3 Windpumping. Practical Action technical brief, PDF hosted by SSWM, pp. 5-6. Retrieved 21 November 2026.
- ↑ 5.0 5.1 5.2 Small Wind Guidebook. U.S. Department of Energy, WINDExchange. Retrieved 21 November 2026.
- ↑ 6.0 6.1 Water Lifting Devices, section 2.1: General principles of water lifting. FAO. Retrieved 21 November 2026.
- ↑ How to Create an Emergency Water Supply. CDC. Retrieved 21 November 2026.