Water wells are openings made to reach groundwater and bring it to the surface. A household well is part of a system that includes the aquifer, the well opening and its protective fittings, the pump, and the pipework to the point of use. Well construction follows the geology of the site. The U.S. Environmental Protection Agency (EPA) describes the principal household well types and components, the Food and Agriculture Organization (FAO) describes hand pumps, and the U.S. Centers for Disease Control and Prevention (CDC) provides the drinking-water testing guidance used here.[1][2][3]

Well types

Type Construction and setting Important limitations
Dug or bored A wide hole is dug to or below the water table. The EPA describes household dug and bored wells as shallow, about 10 to 30 feet deep, and not continuously cased. Water from near the surface can enter the well. A shallow well needs to allow for an abnormally low water table during dry periods.[1][4]
Driven A small-diameter pipe with a screened, pointed end (a sand point) is driven into saturated ground. The EPA gives a usual depth of 30 to 50 feet. Suited to unconsolidated clay, silt and sand relatively free of gravel, cobbles or boulders. Because it draws water from aquifers near the surface, it can be contaminated easily.[1][4]
Drilled A rig drills a borehole, which can be thousands of feet deep, and installs continuous casing. Depth and continuous casing lower the risk of contamination. Casing, screen type and installation method depend on the local geology. A deep well still needs sanitary protection and testing.[1][4][3]

Components and site

Diagram of a landscape with underground storage tanks, landfills, local industry, pesticides and fertilizers, livestock wastes, household wastes and a septic tank, with arrows showing seepage underground toward a well.
Potential sources of well-water contamination include activities above ground. A protected wellhead and a suitable site are complementary safeguards.

Along with grout, the casing keeps dirt and excess water out of the well. At the wellhead, a cap keeps out debris, insects and small animals and includes a vent to control pressure during pumping. A well screen attached to the bottom of the casing keeps too much sediment from entering the well. In climates with frost, a pitless adapter lets the pipe carrying water to the surface stay below the frost line. A screen controls sediment only; drinking-water quality must be assessed separately.[1][3]

The EPA advises locating a well so that rainwater flows away from it, since water pooling near a well can seep into it. When choosing a site, survey nearby septic systems and sewer lines, livestock and other agricultural waste areas, and other operating wells. The NRCS notes that a typical recommended minimum distance between a new well and existing operating wells is 100 feet, but required distances vary by state. Local rules govern the required distances, construction and permits. Keep the construction record and pumping-test results so that later changes in performance can be compared with the original conditions.[1][4]

Water level and yield

The static water level is the depth to water when the well is at rest. During pumping, the water level drops to the pumping water level; the difference is called drawdown. An aquifer test (pumping test) measures the yield and whether the well can sustain pumping at that rate for a long period. The top of the pump intake often limits how much drawdown a well can have, so allow for the lowest expected pumping water level when choosing a pump and setting it in the well. See Groundwater for how nearby wells and dry seasons affect water levels.[4]

Pumps and priming

A pitcher pump has a hand-operated piston and valves at the surface and draws water up a suction pipe. The relevant vertical distance is from the pump to the water surface during use, which can be much less than the total well depth. The FAO describes the pitcher pump as satisfactory where water never needs to be lifted more than about 6 metres, and notes that the maximum suction lift of shallow-well pumps falls by about 1 metre per 1,000 metres of site elevation.[2][note 1]

Priming fills a suction pump with water so it can start working. If the valves leak, the pump must be primed each time it is used, and the priming water can pollute the supply. Use safe water for priming, and repair a pump that repeatedly loses its prime. A deep-well hand pump places the cylinder, plunger and valves down the well, deep enough to be submerged in water at all times, and connects them to the handle with a long rod. Because the cylinder is submerged, the pump is self-priming. Both pitcher and deep-well pumps allow the well top to be completely covered for protection against pollution. Powered wells can instead use a submersible pump in the borehole.[2][4]

Checking drinking-water quality

The CDC recommends testing well water at least once every year for total coliform bacteria, nitrates, total dissolved solids and pH. Contact the local health department to find out what other germs or chemicals to test for where you live. Also test when there are problems near the well, such as flooding, land disturbances or nearby waste disposal sites; when any part of the well system is replaced or repaired; and when the water's taste, color or smell changes. In the United States, use a state-certified laboratory.[3]

Read each result with the local health department's advice. Total coliforms are usually harmless themselves, but their presence means harmful germs are likely to be in the water. E. coli likely means that feces and the germs in them have entered the well water. Water that is too acidic or basic can damage pipes and let metals such as lead leach into the water. Total dissolved solids measure how much material, such as calcium or sodium, is dissolved in the water. If tests show contamination, consider drinking bottled water or another safe source while obtaining advice on the cause and the proper treatment or repair. See Private wells after flooding for the additional precautions a flood requires.[3]

See also

Notes

  1. ↑ The NRCS gives the practical suction lift for pumps as 22 feet at sea level, 17 feet at 5,000 feet elevation and 14 feet at 10,000 feet elevation.[4]

References

  1. ↑ 1.0 1.1 1.2 1.3 1.4 1.5 Learn About Private Water Wells, U.S. Environmental Protection Agency. Retrieved 21 November 2026.
  2. ↑ 2.0 2.1 2.2 Rural water supply and sanitation: Wells; Pumps, in Farm structures, chapter 14, Food and Agriculture Organization of the United Nations. Retrieved 21 November 2026.
  3. ↑ 3.0 3.1 3.2 3.3 3.4 Guidelines for Testing Well Water, Centers for Disease Control and Prevention, 1 July 2024. Retrieved 21 November 2026.
  4. ↑ 4.0 4.1 4.2 4.3 4.4 4.5 4.6 National Engineering Handbook, Part 650, Subpart L: Spring and Well Design, U.S. Department of Agriculture Natural Resources Conservation Service, amended August 2025. Retrieved 21 November 2026.