== Heavy timber framing ==
== Heavy timber framing ==
[[File:Timber frame barn.jpg|thumb|alt=Interior of a barn with large timber posts, horizontal beams, and diagonal bracing|The inside framing of a barn built in the 1880s, showing posts, beams, and diagonal members.]]
[[File:Timber frame barn.jpg|thumb|alt=Interior of a barn with large timber posts, horizontal beams, and diagonal bracing|The inside framing of a barn built in the 1880s, showing posts, beams, and diagonal members.]]
The traditional timber frame is made of large sawn timbers, larger than 5 by 5 inches (114 by 114 mm), connected by hand-fabricated joints such as the mortise and tenon, in which the shaped end of one timber fits into a recess in another. Such a frame involves sophisticated joinery. Secondary rafters or joists may bear on larger beams, and the beams span between posts, which transmit the reactions to the foundations. Diagonal braces, visible in many historic barn frames, link posts and beams and help the frame resist racking. Most barns and factory buildings built in North America before the middle of the 20th century were heavy timber frame.<ref name="fpl" />
The traditional timber frame is made of large sawn timbers, larger than nominal 5 by 5 inches, which the ''Wood Handbook'' gives as a standard (dressed) size of 114 by 114 mm, connected by hand-fabricated joints such as the mortise and tenon, in which the shaped end of one timber fits into a recess in another. Such a frame involves sophisticated joinery. Secondary rafters or joists may bear on larger beams, and the beams span between posts, which transmit the reactions to the foundations. Diagonal braces, visible in many historic barn frames, link posts and beams and help the frame resist racking. Most barns and factory buildings built in North America before the middle of the 20th century were heavy timber frame.<ref name="fpl" />
 
A nominal size names a piece of lumber, while its standard or dressed size is the actual dimension after surfacing and is smaller. The 1955 edition of the ''Wood Handbook'' described posts and timbers as pieces of square or approximately square cross section, 5 by 5 inches (nominal dimensions) and larger, graded primarily for use as posts or columns, with standard surfaced sizes 1/2 inch off each way. Such a grade category describes the stock. The sizes of the members in a particular frame still require a design based on the loads at the site.<ref name="fpl" /><ref name="fpl-1955" /><ref name="wfcm" />


Today's timber frame home is often enclosed by prefabricated composite sheathing panels applied directly to the frame. Whether such panels carry sideways forces or simply enclose space has to be established from the construction details. Local fire regulations should be consulted about the acceptance of the foam insulation in some panels. Because the members have large cross sections, seasoning them before installation is difficult, if not impossible, so they continue to dry in place. The structure must be designed to accommodate the resulting dimensional changes and the seasoning checks that are almost inevitable. Protection from persistent wetting, and inspection of vulnerable details such as joints and post bases, are also important to the durability of the frame.<ref name="fpl" />
Today's timber frame home is often enclosed by prefabricated composite sheathing panels applied directly to the frame. Whether such panels carry sideways forces or simply enclose space has to be established from the construction details. Local fire regulations should be consulted about the acceptance of the foam insulation in some panels. Because the members have large cross sections, seasoning them before installation is difficult, if not impossible, so they continue to dry in place. The structure must be designed to accommodate the resulting dimensional changes and the seasoning checks that are almost inevitable. Protection from persistent wetting, and inspection of vulnerable details such as joints and post bases, are also important to the durability of the frame.<ref name="fpl" />
Line 58: Line 60:
<ref name="wfcm">American Wood Council. [https://awc.org/resources/2024-wfcm/ ''2024 Wood Frame Construction Manual for One- and Two-Family Dwellings'']. Retrieved 21 November 2026.</ref>
<ref name="wfcm">American Wood Council. [https://awc.org/resources/2024-wfcm/ ''2024 Wood Frame Construction Manual for One- and Two-Family Dwellings'']. Retrieved 21 November 2026.</ref>
<ref name="walls">Planning Portal. [https://www.planningportal.co.uk/permission/common-projects/internal-walls/what-building-regulations-apply-to-internal-walls/ What building regulations apply to internal walls?]. England guidance. Retrieved 21 November 2026.</ref>
<ref name="walls">Planning Portal. [https://www.planningportal.co.uk/permission/common-projects/internal-walls/what-building-regulations-apply-to-internal-walls/ What building regulations apply to internal walls?]. England guidance. Retrieved 21 November 2026.</ref>
<ref name="fpl-1955">Forest Products Laboratory. [https://www.govinfo.gov/content/pkg/GOVPUB-A-PURL-gpo18642/pdf/GOVPUB-A-PURL-gpo18642.pdf ''Wood Handbook: Basic Information on Wood as a Material of Construction with Data for Its Use in Design and Specification'']. Agriculture Handbook No. 72, U.S. Department of Agriculture, Forest Service, 1955, chapter on lumber grades and sizes. Retrieved 21 November 2026.</ref>
</references>
</references>


[[Category:Building materials]]
[[Category:Building materials]]

Latest revision as of 02:10, 22 November 2026

Timber framing is the construction of a building's supporting skeleton from wood members and their connections. In its narrower sense, the term describes a frame of large timbers, traditionally joined with fitted carpentry. Light wood framing distributes loads among closely spaced studs, joists, and rafters. Both systems depend on a continuous route for vertical and sideways forces to reach the ground. This article follows the US Forest Products Laboratory's Wood Handbook for the comparison of building systems.[1][2]

Load paths

A continuous load path is the chain of members and connections that resists all the loads acting on a building and carries them to the foundation and ground. When tracing gravity loads, the weight of the building and its contents, start at a roof or floor surface, identify what it rests on, and follow each support down through the building. For wind or earthquake forces, trace the connections too. Wind can lift a roof upward while pushing walls sideways, both perpendicular to a wall and along it. Roof-to-wall connections must carry uplift down to the foundation, and hold-downs and anchors connect walls and floors to the foundation where pieces could otherwise be pulled apart or displaced.[2][1]

Feature Light wood framing Heavy timber framing
Gravity support Many studs, typically spaced 12 to 24 inches (300 to 600 mm) apart, carry loads from upper floors and the roof between top and bottom plates. Large beams collect loads and transfer them to more widely spaced posts, concentrating the reactions at those posts.
Openings A header (lintel) spans a window or door opening and sends the load to the framing at its ends. Open bays occur between main posts. An opening still has to fit the layout of braces, wall panels, and other supports.
Sideways forces Structural panel sheathing, such as plywood or oriented strandboard, provides racking resistance; where the sheathing cannot, diagonal bracing must be used. Diagonal bracing, structural panels or a separate braced or shear-wall system can carry these forces. The design determines which path is used.
Typical connections Nailed framing, with hold-downs, anchors and other connectors where specified. Hand-fabricated joints such as the mortise and tenon in traditional frames.

These are typical arrangements. The governing details are the actual spans, positions of supports, connections, and foundation conditions.[1][2][3]

Light framing

Wooden framing of a house under construction
The wooden frame of a house under construction in the United States.

Platform framing builds each floor on top of the one beneath. Wall framing is erected on the platform formed by the floor joists and subfloor: in most cases an entire wall is framed lying flat on the subfloor and then tilted into place. The walls support the next floor or the roof. Studs are held between horizontal top and bottom plates. Historical balloon framing, used in the early part of the 20th century, instead used full-height wall framing members for two-storey construction. Platform framing has dominated house building since the latter part of the 20th century. Frederick Thomas Hodgson's 1909 book covers balloon, mixed, and heavy timber framing as they were understood at the time.[1][4]

In a light-framed house, a portion of the roof load might pass from a truss to a wall plate, down through studs, and through a lower floor or wall into the foundation. Where a window interrupts that line of studs, the header carries the load across the opening to its supports. Structural panels used as floor, wall and roof sheathing are quicker to install than boards and improve resistance to wind and earthquake loads, and fastened roof and floor panels can help transfer sideways forces to the walls. Shear walls in turn need hold-downs that connect them to the foundation. The continuity of panel fastening, walls, and anchors matters as much as identifying the panels.[1][2][3]

Heavy timber framing

Interior of a barn with large timber posts, horizontal beams, and diagonal bracing
The inside framing of a barn built in the 1880s, showing posts, beams, and diagonal members.

The traditional timber frame is made of large sawn timbers, larger than nominal 5 by 5 inches, which the Wood Handbook gives as a standard (dressed) size of 114 by 114 mm, connected by hand-fabricated joints such as the mortise and tenon, in which the shaped end of one timber fits into a recess in another. Such a frame involves sophisticated joinery. Secondary rafters or joists may bear on larger beams, and the beams span between posts, which transmit the reactions to the foundations. Diagonal braces, visible in many historic barn frames, link posts and beams and help the frame resist racking. Most barns and factory buildings built in North America before the middle of the 20th century were heavy timber frame.[1]

A nominal size names a piece of lumber, while its standard or dressed size is the actual dimension after surfacing and is smaller. The 1955 edition of the Wood Handbook described posts and timbers as pieces of square or approximately square cross section, 5 by 5 inches (nominal dimensions) and larger, graded primarily for use as posts or columns, with standard surfaced sizes 1/2 inch off each way. Such a grade category describes the stock. The sizes of the members in a particular frame still require a design based on the loads at the site.[1][5][3]

Today's timber frame home is often enclosed by prefabricated composite sheathing panels applied directly to the frame. Whether such panels carry sideways forces or simply enclose space has to be established from the construction details. Local fire regulations should be consulted about the acceptance of the foam insulation in some panels. Because the members have large cross sections, seasoning them before installation is difficult, if not impossible, so they continue to dry in place. The structure must be designed to accommodate the resulting dimensional changes and the seasoning checks that are almost inevitable. Protection from persistent wetting, and inspection of vulnerable details such as joints and post bases, are also important to the durability of the frame.[1]

Comparing and assessing frames

Light framing offers many repeated members and can use prefabricated panels, trusses or I-joists. Heavy timber framing organizes the building around larger members and their point supports. A building may combine the two. For example, a lightly framed floor may bear on a large timber girder, and a timber frame may rely on selected panel walls for sideways resistance. Identify each interface when assessing how the parts work together.[1][2]

For a proposed alteration, trace the existing gravity and lateral paths and identify which ones intersect the work. Removing a wall, changing an opening, or cutting a brace or structural panel can change those paths. In England, for example, building regulations normally apply to removing an internal wall or forming an opening in one, and the Planning Portal advises care before removing any internal wall. Building approval and structural assessment depend on the local requirements and the particular building. Member sizes, connections, and foundations require a design based on the loads at the site.[1][3][6]

See also

References

  1. ↑ 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 Wacker, James P. Chapter 17: Use of wood in buildings and bridges. In Wood Handbook: Wood as an Engineering Material, FPL-GTR-282. USDA Forest Service, Forest Products Laboratory, 2021. Retrieved 21 November 2026.
  2. ↑ 2.0 2.1 2.2 2.3 2.4 Building America Solution Center. Continuous Load Path Provided with Connections from the Roof through the Wall to the Foundation. U.S. Department of Energy and Pacific Northwest National Laboratory. Retrieved 21 November 2026.
  3. ↑ 3.0 3.1 3.2 3.3 American Wood Council. 2024 Wood Frame Construction Manual for One- and Two-Family Dwellings. Retrieved 21 November 2026.
  4. ↑ Hodgson, Frederick Thomas. Light and Heavy Timber Framing Made Easy. F. J. Drake & Co., Chicago, 1909. Retrieved 21 November 2026.
  5. ↑ Forest Products Laboratory. Wood Handbook: Basic Information on Wood as a Material of Construction with Data for Its Use in Design and Specification. Agriculture Handbook No. 72, U.S. Department of Agriculture, Forest Service, 1955, chapter on lumber grades and sizes. Retrieved 21 November 2026.
  6. ↑ Planning Portal. What building regulations apply to internal walls?. England guidance. Retrieved 21 November 2026.