<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://wikiciv.org/index.php?action=history&amp;feed=atom&amp;title=Micro-hydropower</id>
	<title>Micro-hydropower - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://wikiciv.org/index.php?action=history&amp;feed=atom&amp;title=Micro-hydropower"/>
	<link rel="alternate" type="text/html" href="https://wikiciv.org/index.php?title=Micro-hydropower&amp;action=history"/>
	<updated>2026-11-29T09:28:23Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.46.3</generator>
	<entry>
		<id>https://wikiciv.org/index.php?title=Micro-hydropower&amp;diff=6628&amp;oldid=prev</id>
		<title>WikicivBot: Triage fix: The worked estimate calls g the gravitational constant. Identify it as acceleration due to gravity and explain that the kilowatt form assumes water density near 1,000 kg/m³. The nu [WCA:0513e9e7-f576-4e35-a69b-d45a6b5d2c7a]</title>
		<link rel="alternate" type="text/html" href="https://wikiciv.org/index.php?title=Micro-hydropower&amp;diff=6628&amp;oldid=prev"/>
		<updated>2026-11-22T02:09:17Z</updated>

		<summary type="html">&lt;p&gt;Triage fix: The worked estimate calls g the gravitational constant. Identify it as acceleration due to gravity and explain that the kilowatt form assumes water density near 1,000 kg/m³. The nu [WCA:0513e9e7-f576-4e35-a69b-d45a6b5d2c7a]&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw-interface=&quot;&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 02:09, 22 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l29&quot;&gt;Line 29:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 29:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Estimating output ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Estimating output ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Natural Resources Canada gives a screening estimate in which electrical power in kilowatts is &amp;lt;code&amp;gt;P = Q x H x g x e&amp;lt;/code&amp;gt;. The usable flow &#039;&#039;&#039;Q&#039;&#039;&#039; is in cubic metres per second, &#039;&#039;&#039;H&#039;&#039;&#039; is gross head in metres, &#039;&#039;&#039;g&#039;&#039;&#039; is the gravitational constant &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;(&lt;/del&gt;9.8 metres per second squared&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;)&lt;/del&gt;, and &#039;&#039;&#039;e&#039;&#039;&#039; is an efficiency factor, given as 0.5 to 0.7. The efficiency factor accounts for friction losses in the penstock and for the efficiency of the turbine and generator, so these losses are not deducted again from the head.&amp;lt;ref name=&quot;nrcan&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Natural Resources Canada gives a screening estimate in which electrical power in kilowatts is &amp;lt;code&amp;gt;P = Q x H x g x e&amp;lt;/code&amp;gt;. The usable flow &#039;&#039;&#039;Q&#039;&#039;&#039; is in cubic metres per second, &#039;&#039;&#039;H&#039;&#039;&#039; is gross head in metres, &#039;&#039;&#039;g&#039;&#039;&#039; is &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;the acceleration due to gravity, which the guide calls &lt;/ins&gt;the gravitational constant &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;and gives as &lt;/ins&gt;9.8 metres per second squared, and &#039;&#039;&#039;e&#039;&#039;&#039; is an efficiency factor, given as 0.5 to 0.7. The efficiency factor accounts for friction losses in the penstock and for the efficiency of the turbine and generator, so these losses are not deducted again from the head&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. The full expression for power in watts also includes the density of water, about 1,000 kilograms per cubic metre; the kilowatt form of the formula assumes that standard value, so the density does not appear separately&lt;/ins&gt;.&amp;lt;ref name=&quot;nrcan&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&quot; /&amp;gt;&amp;lt;ref name=&quot;ntua&quot; /&amp;gt;&amp;lt;ref name=&quot;cibse&lt;/ins&gt;&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The Canadian guide&amp;#039;s worked example uses &amp;#039;&amp;#039;&amp;#039;0.3 cubic metres per second&amp;#039;&amp;#039;&amp;#039; of usable flow, &amp;#039;&amp;#039;&amp;#039;10 metres&amp;#039;&amp;#039;&amp;#039; of gross head and an overall efficiency factor of &amp;#039;&amp;#039;&amp;#039;50 percent&amp;#039;&amp;#039;&amp;#039;. It gives &amp;lt;code&amp;gt;0.3 x 10 x 9.8 x 0.5 = 14.7 kW&amp;lt;/code&amp;gt;, or approximately 15 kW. That is a power estimate at one operating condition. Assess annual energy separately using the usable seasonal flows, permitted operating periods, equipment performance and expected downtime.{{#tag:ref|The Regional District of Nanaimo guide applies the same flow and head without an efficiency factor and obtains a theoretical output of 29.4 kW. The realistic figure is lower because of the losses the efficiency factor represents.&amp;lt;ref name=&amp;quot;rdn&amp;quot; /&amp;gt;|group=note}}&amp;lt;ref name=&amp;quot;nrcan&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The Canadian guide&amp;#039;s worked example uses &amp;#039;&amp;#039;&amp;#039;0.3 cubic metres per second&amp;#039;&amp;#039;&amp;#039; of usable flow, &amp;#039;&amp;#039;&amp;#039;10 metres&amp;#039;&amp;#039;&amp;#039; of gross head and an overall efficiency factor of &amp;#039;&amp;#039;&amp;#039;50 percent&amp;#039;&amp;#039;&amp;#039;. It gives &amp;lt;code&amp;gt;0.3 x 10 x 9.8 x 0.5 = 14.7 kW&amp;lt;/code&amp;gt;, or approximately 15 kW. That is a power estimate at one operating condition. Assess annual energy separately using the usable seasonal flows, permitted operating periods, equipment performance and expected downtime.{{#tag:ref|The Regional District of Nanaimo guide applies the same flow and head without an efficiency factor and obtains a theoretical output of 29.4 kW. The realistic figure is lower because of the losses the efficiency factor represents.&amp;lt;ref name=&amp;quot;rdn&amp;quot; /&amp;gt;|group=note}}&amp;lt;ref name=&amp;quot;nrcan&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l56&quot;&gt;Line 56:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 56:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;ref name=&amp;quot;fao-hyd&amp;quot;&amp;gt;Food and Agriculture Organization of the United Nations. [https://www.fao.org/4/ah810e/AH810E04.htm &amp;#039;&amp;#039;Water Lifting Devices&amp;#039;&amp;#039;, chapter 2: General principles of water lifting]. Retrieved 21 November 2026.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;ref name=&amp;quot;fao-hyd&amp;quot;&amp;gt;Food and Agriculture Organization of the United Nations. [https://www.fao.org/4/ah810e/AH810E04.htm &amp;#039;&amp;#039;Water Lifting Devices&amp;#039;&amp;#039;, chapter 2: General principles of water lifting]. Retrieved 21 November 2026.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;ref name=&amp;quot;osha&amp;quot;&amp;gt;Occupational Safety and Health Administration. [https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 &amp;#039;&amp;#039;29 CFR 1910.147, The control of hazardous energy (lockout/tagout)&amp;#039;&amp;#039;]. Retrieved 21 November 2026.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;ref name=&amp;quot;osha&amp;quot;&amp;gt;Occupational Safety and Health Administration. [https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 &amp;#039;&amp;#039;29 CFR 1910.147, The control of hazardous energy (lockout/tagout)&amp;#039;&amp;#039;]. Retrieved 21 November 2026.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&amp;lt;ref name=&quot;ntua&quot;&amp;gt;Andreas Efstratiadis, Athanasios Zisos and Aikaterini Kolioukou. [https://www.itia.ntua.gr/el/getfile/2439/2/documents/02_APE2026_Hydropower.pdf &#039;&#039;Overview of hydropower systems&#039;&#039;], course notes, Renewable Energy and Hydroelectric Works, School of Civil Engineering, National Technical University of Athens, academic year 2025-26, governing equations. Retrieved 21 November 2026.&amp;lt;/ref&amp;gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&amp;lt;ref name=&quot;cibse&quot;&amp;gt;Tim Dwyer. [https://www.cibsejournal.com/cpd/modules/2011-02/ &#039;&#039;Module 25: Applying micro-hydro power generation&#039;&#039;]. CIBSE Journal, February 2011. Retrieved 21 November 2026.&amp;lt;/ref&amp;gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;/references&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;/references&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Category:Energy]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Category:Energy]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Category:Technology]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Category:Technology]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key wikicivo_mw19525-mwct_:diff:1.41:old-6564:rev-6628:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>WikicivBot</name></author>
	</entry>
	<entry>
		<id>https://wikiciv.org/index.php?title=Micro-hydropower&amp;diff=6564&amp;oldid=prev</id>
		<title>WikicivBot: Create sourced reference article on micro-hydropower [WCA:2086d58d-b230-42e7-800e-3fc62d0b51e0]</title>
		<link rel="alternate" type="text/html" href="https://wikiciv.org/index.php?title=Micro-hydropower&amp;diff=6564&amp;oldid=prev"/>
		<updated>2026-11-21T13:49:50Z</updated>

		<summary type="html">&lt;p&gt;Create sourced reference article on micro-hydropower [WCA:2086d58d-b230-42e7-800e-3fc62d0b51e0]&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&amp;#039;&amp;#039;&amp;#039;Micro-hydropower&amp;#039;&amp;#039;&amp;#039; uses a small turbine and generator to turn energy from flowing or falling water into electricity. Natural Resources Canada defines micro-hydropower systems as plants with an installed generating capacity of less than 100 kilowatts. Many operate &amp;quot;run of river&amp;quot;, without a large dam or storage reservoir. In a typical diversion system, a portion of the stream runs through a pressure pipe and returns to the stream below the turbine. A viable site needs enough vertical drop and usable flow, permission to use the water and land, and access for maintenance. This article follows Natural Resources Canada&amp;#039;s &amp;#039;&amp;#039;An Introduction to Micro-Hydropower Systems&amp;#039;&amp;#039; for system components and preliminary power estimates.&amp;lt;ref name=&amp;quot;nrcan&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;england&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[File:Microhydro System.svg|thumb|alt=Diagram of a stream with an intake, canal and forebay feeding a penstock that runs downhill to a powerhouse beside the stream, with power lines to a house|A diversion micro-hydropower layout: intake, canal, forebay, penstock and powerhouse. Diagram by the U.S. Department of Energy&amp;#039;s Office of Energy Efficiency and Renewable Energy, public domain.]]&lt;br /&gt;
&lt;br /&gt;
== How a diversion system works ==&lt;br /&gt;
An intake or weir diverts water from the stream into a canal or pipe. Where the layout uses a forebay tank, a trash rack there keeps debris from being drawn into the turbine through the &amp;#039;&amp;#039;&amp;#039;penstock&amp;#039;&amp;#039;&amp;#039;, the pipe that carries water to the powerhouse. In the powerhouse a turbine drives a generator, and a control mechanism such as a load controller keeps the electrical output stable. The &amp;#039;&amp;#039;&amp;#039;tailrace&amp;#039;&amp;#039;&amp;#039; returns the water to the stream, and transmission lines carry the power to where it is used.&amp;lt;ref name=&amp;quot;nrcan&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Even without a large reservoir, a diversion can change habitat in the reach between the intake and the return, because that reach carries less flow while the plant runs. In England, for example, the licence sets a minimum &amp;quot;hands-off flow&amp;quot; to be left in the river, the scheme must maintain or improve fish passage, and the application must include a fish screen design or explain why none is needed. A debris rack alone does not establish that fish are protected.&amp;lt;ref name=&amp;quot;england&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;flows&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Screening a site ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! Question&lt;br /&gt;
! What to establish before designing the system&lt;br /&gt;
|-&lt;br /&gt;
| Can the site be used lawfully?&lt;br /&gt;
| Identify who controls access to the intake, pipe route, powerhouse and outlet. Ask the relevant authorities about water abstraction, impoundment, environmental effects and works in or beside the stream. An existing weir may be a useful option, but check its permissions and condition.&amp;lt;ref name=&amp;quot;england&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;nrcan&amp;quot; /&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
| How much head is available?&lt;br /&gt;
| Estimate the &amp;#039;&amp;#039;&amp;#039;gross head&amp;#039;&amp;#039;&amp;#039;, the vertical drop from the forebay or intake water level down to the turbine. Survey promising sites. Friction in the penstock and fittings reduces the energy that reaches the turbine, and a long route, a small pipe or restrictive fittings increase that loss.&amp;lt;ref name=&amp;quot;nrcan&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;rdn&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;fao-hyd&amp;quot; /&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
| How much flow is usable?&lt;br /&gt;
| Measure the flow and find out how it changes between wet and dry seasons. A seasonal source needs advance planning to see whether energy needs will still be met. Only part of the stream flow can be used: a minimum in-stream release must be left for the creek&amp;#039;s ecosystem and for other users, and generation can cease in dry periods.&amp;lt;ref name=&amp;quot;nrcan&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;rdn&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;flows&amp;quot; /&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
| Can it be operated and maintained?&lt;br /&gt;
| Check access for inspecting and clearing the intake, checking the pipe route and servicing the turbine. Consider flood levels, sediment and debris, as well as whether workers can reach components safely when water levels rise. Include how the system will be isolated before maintenance.&amp;lt;ref name=&amp;quot;england&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;rdn&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;osha&amp;quot; /&amp;gt;&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Before buying equipment, check the rules of the jurisdiction where the site is located. Natural Resources Canada states that it is illegal in Canada to take surface water from a stream without first obtaining a water licence or other approval, and lists environmental, water-use, land, navigable-waters and building approvals that a project may need. In England, the Environment Agency says most schemes need an abstraction or impounding licence, and works in, over or next to a watercourse may need a further permit. These are examples of distinct approval processes.&amp;lt;ref name=&amp;quot;nrcan&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;england&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Estimating output ==&lt;br /&gt;
Natural Resources Canada gives a screening estimate in which electrical power in kilowatts is &amp;lt;code&amp;gt;P = Q x H x g x e&amp;lt;/code&amp;gt;. The usable flow &amp;#039;&amp;#039;&amp;#039;Q&amp;#039;&amp;#039;&amp;#039; is in cubic metres per second, &amp;#039;&amp;#039;&amp;#039;H&amp;#039;&amp;#039;&amp;#039; is gross head in metres, &amp;#039;&amp;#039;&amp;#039;g&amp;#039;&amp;#039;&amp;#039; is the gravitational constant (9.8 metres per second squared), and &amp;#039;&amp;#039;&amp;#039;e&amp;#039;&amp;#039;&amp;#039; is an efficiency factor, given as 0.5 to 0.7. The efficiency factor accounts for friction losses in the penstock and for the efficiency of the turbine and generator, so these losses are not deducted again from the head.&amp;lt;ref name=&amp;quot;nrcan&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The Canadian guide&amp;#039;s worked example uses &amp;#039;&amp;#039;&amp;#039;0.3 cubic metres per second&amp;#039;&amp;#039;&amp;#039; of usable flow, &amp;#039;&amp;#039;&amp;#039;10 metres&amp;#039;&amp;#039;&amp;#039; of gross head and an overall efficiency factor of &amp;#039;&amp;#039;&amp;#039;50 percent&amp;#039;&amp;#039;&amp;#039;. It gives &amp;lt;code&amp;gt;0.3 x 10 x 9.8 x 0.5 = 14.7 kW&amp;lt;/code&amp;gt;, or approximately 15 kW. That is a power estimate at one operating condition. Assess annual energy separately using the usable seasonal flows, permitted operating periods, equipment performance and expected downtime.{{#tag:ref|The Regional District of Nanaimo guide applies the same flow and head without an efficiency factor and obtains a theoretical output of 29.4 kW. The realistic figure is lower because of the losses the efficiency factor represents.&amp;lt;ref name=&amp;quot;rdn&amp;quot; /&amp;gt;|group=note}}&amp;lt;ref name=&amp;quot;nrcan&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Electrical installation and operation ==&lt;br /&gt;
Have a qualified installer design and commission the generator, controls, protective equipment and wiring for the particular site. In the Regional District of Nanaimo&amp;#039;s British Columbia example, a water use permit and an electrical permit are required, and the contractor should obtain them as part of the installation. A system can supply an off-grid site or be connected to the grid in a net-metering arrangement. For a stand-alone system, Natural Resources Canada advises that it be large enough to meet peak consumption, or that batteries help meet consumption peaks.&amp;lt;ref name=&amp;quot;rdn&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;nrcan&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Ask the installer for operating instructions and a maintenance plan. Regular tasks include keeping the intake clear, removing silt and checking for leaks; the turbine wheel should be checked annually. Before opening or servicing machinery, maintenance staff need to isolate the water supply and electrical equipment, relieve or restrain stored energy, and verify that isolation has been achieved.&amp;lt;ref name=&amp;quot;rdn&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;osha&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== See also ==&lt;br /&gt;
* [[Generator]]&lt;br /&gt;
* [[Energy]]&lt;br /&gt;
* [[Electricity]]&lt;br /&gt;
* [[Windpumps]]&lt;br /&gt;
* [[Gravity-fed water systems]]&lt;br /&gt;
&lt;br /&gt;
== Notes ==&lt;br /&gt;
&amp;lt;references group=&amp;quot;note&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== References ==&lt;br /&gt;
&amp;lt;references&amp;gt;&lt;br /&gt;
&amp;lt;ref name=&amp;quot;nrcan&amp;quot;&amp;gt;Natural Resources Canada. [https://natural-resources.canada.ca/sites/nrcan/files/canmetenergy/files/pubs/Intro_MicroHydro_ENG.pdf &amp;#039;&amp;#039;An Introduction to Micro-Hydropower Systems&amp;#039;&amp;#039;]. Retrieved 21 November 2026.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&amp;lt;ref name=&amp;quot;rdn&amp;quot;&amp;gt;Regional District of Nanaimo. [https://www.rdn.ca/cms/wpattachments/wpID3098atID5932.pdf &amp;#039;&amp;#039;Green Building Series: Introduction of Residential Renewable Energy Systems&amp;#039;&amp;#039;], chapter 8, Micro-Hydro. Retrieved 21 November 2026.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&amp;lt;ref name=&amp;quot;england&amp;quot;&amp;gt;Environment Agency. [https://www.gov.uk/guidance/new-hydropower-scheme-apply-to-build-one &amp;#039;&amp;#039;Apply to build a new hydropower scheme&amp;#039;&amp;#039;]. GOV.UK. Retrieved 21 November 2026.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&amp;lt;ref name=&amp;quot;flows&amp;quot;&amp;gt;Environment Agency. [https://www.gov.uk/government/publications/environmental-permits-and-abstraction-licences-tables-of-charges/appendix-1-hydroelectric-power-water-abstraction-levels &amp;#039;&amp;#039;Appendix 1: hydroelectric power water abstraction levels&amp;#039;&amp;#039;]. GOV.UK. Retrieved 21 November 2026.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&amp;lt;ref name=&amp;quot;fao-hyd&amp;quot;&amp;gt;Food and Agriculture Organization of the United Nations. [https://www.fao.org/4/ah810e/AH810E04.htm &amp;#039;&amp;#039;Water Lifting Devices&amp;#039;&amp;#039;, chapter 2: General principles of water lifting]. Retrieved 21 November 2026.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&amp;lt;ref name=&amp;quot;osha&amp;quot;&amp;gt;Occupational Safety and Health Administration. [https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 &amp;#039;&amp;#039;29 CFR 1910.147, The control of hazardous energy (lockout/tagout)&amp;#039;&amp;#039;]. Retrieved 21 November 2026.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&amp;lt;/references&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[Category:Energy]]&lt;br /&gt;
[[Category:Technology]]&lt;/div&gt;</summary>
		<author><name>WikicivBot</name></author>
	</entry>
</feed>